Diagnose & fix common faults

Acetylene Plant Troubleshooting: Common Problems, Causes & Remedies

Operation & Maintenance·10 min read·Updated 9 Jul 2026

Most acetylene-plant faults have a handful of well-known causes, and nearly all are safe to correct once you know where to look. This guide walks the plant the way an IIGAS engineer does — generator, feed, hydraulics, safety devices, then compressor and driers — with the probable cause and remedy for each common symptom. When in doubt about a cause or a fix, stop and call us.

Before you start: work safely

Acetylene is flammable and the plant runs on live water, gas and electrical systems. Diagnose with the plant in a known state, isolate before you open anything, and never test for leaks with a flame — always soap solution. If a fault involves the flashback arrestors, safety valves or pressure switches, treat it as safety-critical and do not defeat the interlock to keep running.

Generator — water level and temperature

The generator alarms are your first line of defence. A low-water alarm means the reaction can run hot and dry; a high-temperature alarm means the carbide-to-water ratio or cooling is off. Both trip the carbide feed by design.

SymptomProbable causeRemedy
Low-water alarm ringsWater level has dropped below the low markConfirm on the low-water check valve; add water via the by-pass or water-control valve; check the slurry-drain valve and its instrument-air line for leaks
High-water alarm ringsWater level above the high mark, or a faulty level transmitterDrain to level; if no leaks, clean or change the level-transmitter diaphragm; confirm on the upper check valve
High-temperature alarmLow water supply, inlet valve not opening, or wrong water-to-carbide ratioRaise water-supply pressure; check the water-control valve; reset the inlet-water instrument so the ratio is 3–4 litre per kg carbide; clean the generator spray nozzles if dirty
Bottom of tank a different temperature to just below water levelInsufficient agitation of the sludgeCheck the agitator is turning at the far end; increase the agitator run time; if carbide dust is 10%+, run the agitator longer

Carbide feed and hydraulics

If the generator pressure will not hold or the screw feed stalls, the problem is almost always in the carbide feed, the hydraulic pump that drives the hopper valves, or an electrical trip.

SymptomProbable causeRemedy
No gas generationCarbide not falling into the generator — bridged hopper, oversized lumps, or reverse screw-feed rotationWeed out oversized carbide; tap a bridged hopper neck with a wooden mallet; correct the screw-feed direction; recharge if empty
Screw feed will not runHopper starter overload tripped, water level too high/low, temperature too high, or low air supplyReset the hopper-starter overload; correct water level and instruments; reduce temperature; restore air-supply pressure
Screw-feed motor overloads or shears its pin oftenSprocket mis-alignment, worn shaft/bushes, or carbide chips jammed in the housingRe-align the sprockets; inspect and change worn parts, clean and lubricate the bushings; remove trapped carbide chips
Hydraulic oil pressure not developing (gauge below 5 kg/cm²g)Low oil level, by-pass valve open too wide, or reverse pump rotationTop up oil; close the by-pass then open ¾–1 turn; correct the pump direction; re-calibrate a faulty gauge
Reduction gearbox overheats or buzzesWrong / low / excess lubricant, damaged gear, or worn bearingsSet oil to the specified grade and level; replace damaged gears or bearings; check the actual loading

Slurry drain, agitator and safety valves

SymptomProbable causeRemedy
Slurry drain valve not opening at set levelInstrument-air leak to the valve, or a punctured drain-valve diaphragmLocate and arrest the air leak; change the diaphragm (Parts B-02/B-03)
Slurry not draining, level keeps risingClogged slurry line or a non-functioning level transmitterDrain through the bottom plug and flush the generator and pipe with fresh water; clean or change the transmitter diaphragm
Agitator gland leakageLoose gland nut or worn asbestos packingTighten the gland nut moderately; a slight leak often self-seals — if it continues, add / change packing and apply grease
Safety valve passes below set pressureForeign particles on the seat, or the setting disturbedClean the seat (replace if damaged); reset the safety valve to its correct pressure
Gas leak through a safety-valve manual vent armRuptured safety-valve diaphragmChange the diaphragm

Pressure switches, cooler-condenser and scrubber

SymptomProbable causeRemedy
Pressure switch not actuating at cut-outClogged impulse line, punctured Bourdon tube, or obstructed switch bulbClean and flush the impulse line then purge with nitrogen; locate and rectify the leak; free the switch bulb movement
Gas leaving cooler-condenser above room temperatureInsufficient cooling-water flow, or air trapped in the water sectionIncrease cooling-water flow; open the water valve to vent trapped air
Lime build-up in the cooler-condenser (typically after 4–6 years, sooner on dusty carbide)Scale forming in the pipework / outlet cellClean the pipe wherever build-up is found; clean the check valve ahead of the scrubber
Pressure drop from generator to compressor above normalFlashback-arrestor check valve clogged, or arrestor filled with sludgeReplace the check valve; vent and clean out the flashback arrestor and its horizontal pipe

Acetylene compressor and high-pressure driers

Compressor symptoms nearly always trace to worn valves, worn rings, an oil problem, or a mis-set pressure switch. Cylinder-filling delays and rapid safety-valve discharge are the two you will meet most.

SymptomProbable causeRemedy
Compressor will not startNo / single-phase power, defective motor-starter, or low suction pressure tripping the LP switchConfirm three-phase supply; rectify the starter; raise generator pressure; check free rotation and keep interstage purge valves open
Cylinder filling slower than normalWorn piston rings (or first-stage valves leaking)Check and replace the piston rings; clean or lap the first-stage valves
Interstage / final-stage safety valve discharges rapidlyLeaky or dirty stage valves, or an isolation valve stuck shutRemove the affected stage head and clean the valves; replace a broken valve or spring; open a stuck isolation valve
Compressor oil pressure below 0.5 kg/cm²gBroken oil-pump belt, low oil, clogged oil suction line, or defective oil pumpFit a loose (not tight) oil-pump belt; top up oil; clean the suction line; repair or replace the pump
Compressor oil turns greyWater in the crankcase, or detergent oil usedDrain the oil-and-water emulsion and refill with the correct non-detergent grade; find and repair the water leak
Compressor stops before max charging pressureHP pressure switch set too low, or a mis-calibrated gaugeReset the high indicator to 24 kg/cm²g / low to 3 kg/cm²g; re-calibrate so it trips at the true pressure
HP drier condensate-drain valve clogs repeatedlyNot enough flushing water for the temperature changeUse more water when flushing; if nothing drains, isolate, vent the drier and clean or replace the valve

One rule underlies the whole compressor table: never run the machine harder to overcome a fault. Rapid safety-valve discharge, slow filling or falling oil pressure are all telling you to stop and fix the cause.

When to stop and call IIGAS

Correct the routine faults above with confidence. But stop the plant and call us if a flashback arrestor is bypassed or damaged, if a safety valve will not reseat, if gas leaks persist after the obvious remedy, or if any fault repeats after being "fixed" — a recurring fault is a symptom of a deeper cause. As the plant builder we can diagnose from your log-book readings and get you running safely.

Frequently asked questions

The water level has dropped below the low mark. Confirm on the low-water check valve, then add water through the by-pass or water-control valve. If it recurs, check the slurry-drain valve and its instrument-air line for leaks — an air leak to the drain valve can bleed water out faster than it is replaced.
High generator temperature usually means low water supply, a water-inlet valve that is not opening, or a wrong water-to-carbide ratio. Raise the water-supply pressure, check the water-control valve, reset the inlet-water instrument to a 3–4 litre-per-kg ratio, and clean the generator spray nozzles if they are dirty. The temperature trip will cut the carbide feed to protect the plant.
Common causes are a tripped hopper-starter overload, water level too high or too low, generator temperature too high, or low instrument-air pressure. Reset the overload, correct the water level and instruments, reduce the temperature, and restore air pressure. If it runs but no gas is generated, the carbide may be bridged in the hopper or the screw may be turning in reverse.
The usual cause is worn piston rings; leaking first-stage valves are the next suspect. Check and replace the rings, and clean or lap the first-stage valves. Do not raise the pressure to compensate — that accelerates the wear.
Grey oil means water has entered the crankcase, or a detergent oil has been used and emulsified. Drain the oil-and-water mixture, refill with the correct non-detergent grade, and find and repair the water leak before running — grey oil will not protect the bores.
Stop and call the builder if a flashback arrestor is bypassed or damaged, a safety valve will not reseat, gas leaks persist after the obvious fix, or any fault recurs after being corrected. A repeating fault points to a deeper cause that needs proper diagnosis rather than a repeated patch.